102 research outputs found

    Quantifying the ki-67 heterogeneity profile in prostate cancer.

    Get PDF
    BackgroundKi-67 is a robust predictive/prognostic marker in prostate cancer; however, tumor heterogeneity in prostate biopsy samples is not well studied.MethodsUsing an MRI/US fusion device, biopsy cores were obtained systematically and by targeting when indicated by MRI. Prostate cores containing cancer from 77 consecutive men were analyzed. The highest Ki-67 was used to determine interprostatic variation. Ki-67 range (highest minus lowest) was used to determine intraprostatic and intralesion variation. Apparent diffusion coefficient (ADC) values were evaluated in relation to Ki-67.ResultsInterprostatic Ki-67 mean ± standard deviation (SD) values for NCCN low (L), intermediate (I), and high (H) risk patients were 5.1 ± 3.8%, 7.4 ± 6.8%, and 12.0 ± 12.4% (ANOVA P = 0.013). Intraprostatic mean ± SD Ki-67 ranges in L, I, and H risk patients were 2.6 ± 3.6%, 5.3 ± 6.8%, and 10.9 ± 12.3% (ANOVA P = 0.027). Intralesion mean ± SD Ki-67 ranges in L, I, and H risk patients were 1.1 ± 0.9%, 5.2 ± 7.9%, and 8.1 ± 10.8% (ANOVA P = 0.22). ADC values at Ki-67 > and <7.1% were 860 ± 203 and 1036 ± 217, respectively (P = 0.0029).ConclusionsHigh risk patients have significantly higher inter- and intraprostatic Ki-67 heterogeneity. This needs to be considered when utilizing Ki-67 clinically

    Health-Related Quality of Life After Stereotactic Body Radiation Therapy for Localized Prostate Cancer: Results From a Multi-institutional Consortium of Prospective Trials

    Get PDF
    PurposeTo evaluate the early and late health-related quality of life (QOL) outcomes among prostate cancer patients following stereotactic body radiation therapy (SBRT).Methods and MaterialsPatient self-reported QOL was prospectively measured among 864 patients from phase 2 clinical trials of SBRT for localized prostate cancer. Data from the Expanded Prostate Cancer Index Composite (EPIC) instrument were obtained at baseline and at regular intervals up to 6 years. SBRT delivered a median dose of 36.25 Gy in 4 or 5 fractions. A short course of androgen deprivation therapy was given to 14% of patients.ResultsMedian follow-up was 3 years and 194 patients remained evaluable at 5 years. A transient decline in the urinary and bowel domains was observed within the first 3 months after SBRT which returned to baseline status or better within 6 months and remained so beyond 5 years. The same pattern was observed among patients with good versus poor baseline function and was independent of the degree of early toxicities. Sexual QOL decline was predominantly observed within the first 9 months, a pattern not altered by the use of androgen deprivation therapy or patient age.ConclusionLong-term outcome demonstrates that prostate SBRT is well tolerated and has little lasting impact on health-related QOL. A transient and modest decline in urinary and bowel QOL during the first few months after SBRT quickly recovers to baseline levels. With a large number of patients evaluable up to 5 years following SBRT, it is unlikely that unexpected late adverse effects will manifest themselves

    Long-Term (10-Year) Gastrointestinal and Genitourinary Toxicity after Treatment with External Beam Radiotherapy, Radical Prostatectomy, or Brachytherapy for Prostate Cancer

    Get PDF
    Objective.To examine gastrointestinal (GI) and genitourinary (GU) toxicity profiles of patients treated in 1999 with external beam radiotherapy (RT), prostate interstitial brachytherapy (PI) or radical prostatectomy (RP). Methods. TThe records of 525 patients treated in 1999 were reviewed to evaluate toxicity. Late GI and GU morbidities were graded according to the RTOG late morbidity criteria. Other factors examined were patient age, BMI, smoking history, and medical co-morbidities. Due to the low event rate for late GU and GI toxicities, a competing risk regression (CRR) analysis was done with death as the competing event. Results. Median follow-up time was 8.5 years. On CRR univariate analysis, only the presence of DM was significantly associated with GU toxicity grade >2 (P = 0.43, HR 2.35, 95% Cl = 1.03–5.39). On univariate analysis, RT and DM were significantly associated with late GI toxicity. On multivariable analysis, both variables remained significant (RT: P = 0.038, HR = 4.71, CI = 1.09–20.3; DM: P = 0.008, HR = 3.81, 95% Cl = 1.42–10.2). Conclusions. Late effects occur with all treatment modalities. The presence of DM at the time of treatment was significantly associated with worse late GI and GU toxicity. RT was significantly associated with worse late GI toxicity compared to PI and RP

    RapidPlan Hippocampal Sparing Whole Brain Model Version 2-How far can we reduce the dose?

    Get PDF
    Whole-brain radiotherapy has been the standard palliative treatment for patients with brain metastases due to its effectiveness, availability, and ease of administration. Recent clinical trials have shown that limiting radiation dose to the hippocampus is associated with decreased cognitive toxicity. In this study, we updated an existing Knowledge Based Planning model to further reduce dose to the hippocampus and improve other dosimetric plan quality characteristics. Forty-two clinical cases were contoured according to guidelines. A new dosimetric scorecard was created as an objective measure for plan quality. The new Hippocampal Sparing Whole Brain Version 2 (HSWBv2) model adopted a complex recursive training process and was validated with five additional cases. HSWBv2 treatment plans were generated on the Varian Halcyo

    Prostate Intrafraction Translation Margins for Real-Time Monitoring and Correction Strategies

    Get PDF
    The purpose of this work is to determine appropriate radiation therapy beam margins to account for intrafraction prostate translations for use with real-time electromagnetic position monitoring and correction strategies. Motion was measured continuously in 35 patients over 1157 fractions at 5 institutions. This data was studied using van Herk's formula of (αΣ + γσ') for situations ranging from no electromagnetic guidance to automated real-time corrections. Without electromagnetic guidance, margins of over 10 mm are necessary to ensure 95% dosimetric coverage while automated electromagnetic guidance allows the margins necessary for intrafraction translations to be reduced to submillimeter levels. Factors such as prostate deformation and rotation, which are not included in this analysis, will become the dominant concerns as margins are reduced. Continuous electromagnetic monitoring and automated correction have the potential to reduce prostate margins to 2-3 mm, while ensuring that a higher percentage of patients (99% versus 90%) receive a greater percentage (99% versus 95%) of the prescription dose